Art. 26600 / 26608 – Horizontal security solenoid bolt for interlock – Fail Safe
Security strip solenoid bolt for intensive and continuous use, with insertion on the leaf, for aluminium or steel doors in single (blocks of flats, offices, companies...) or interlocked (banks, jewellers, institutions...) configuration, can be combined with intercoms and access control systems. Stainless steel front and counterplate (with counterplate equipped with alignment magnet) and rotating bolt in hardened, anti-cut and anti-burglary steel, with mechanical lock in closed position. Open in the absence of power supply. Equipped with internal microprocessor control electronics and quick-connect connector, mechanical opening with European cylinder or handle and automatic reclosing with adjustable timings (timings can be switched off for use of the solenoid bolt with external control electronics).
N.B.: the European profile shaped cylinder can be purchased separately.
PRODUCT CODE:
EMPLOYMENT:
PACKAGE:
VARIANTS:
CHARACTERISTICS:
SPECIFICATIONS:
| Lock front dimensions | 160 x 25 x 3 mm |
| Counterplate front dimensions | 150 x 25 x 3 mm |
| Lock body dimensions | 77 x 22 x 210 mm |
| Standard deadbolt dimensions | Diameter ø 16 mm Extension 20 mm |
| Deadbolt dimensions XL | Diameter ø 16 mm Extension 25 mm |
| Power supply | 10 to 30 Vdc |
| Inrush current consumption | 2,5 / 3 A |
| Continuously electronically controlled holding current | 130 - 230 mA |
| Mechanical opening | European cylinder Handle N.B.: cylinder with inside knob cannot be used |
| Revenue available on the same mechanics | 70 and 90 mm |
| Functions: | |
| N.A. Commands of | Opening Block Emergency Reset Alarms |
| Deadbolt position contact | C. / N.A. / N.C. |
| Door position contact N.O. | For monitoring function Open / Closed For the use of an external door alignment sensor |
| Open Collector Alarm Contact for | Prolonged door opening from 0 to 120 sec. Failure Emergency Simultaneous opening of 2 or more doors when connected in interlocking configuration |
| Checking the bolt position | Opto-electronic control |
| Sash position sensor | Internal magnetic sensor |
| Buttons for monitoring and adjusting | Closing times Prolonged Door Open Alarm Trigger Time (function can be switched off) |
| Closing times | 0 to 5 sec. when door is approached 0 to 60 sec if the door is not opened |
| Codes | |
| 26600 | Without handle panel |
| 26608 | With 8 mm handle square |
| Art. + XL | Extended deadbolt extension + 5 mm |
| Art. + SA | Solenoid bolt with anti-rebound alignment ball mounted directly on the armature plate with ABS slide on the front |
| Art. + SAXL | Solenoid bolt with anti-rebound alignment ball and increased bolt extension + 5 mm |